{"id":493,"date":"2008-03-01T18:48:27","date_gmt":"2008-03-01T18:48:27","guid":{"rendered":"https:\/\/informatech.energir.com\/?p=493"},"modified":"2021-04-15T08:11:55","modified_gmt":"2021-04-15T13:11:55","slug":"quatre-moyens-doptimiser-la-performance-energetique-des-chaudieres-commerciales-et-industrielles","status":"publish","type":"post","link":"https:\/\/dev.informatech.colpron.com\/?p=493","title":{"rendered":"Quatre moyens d\u2019optimiser la performance \u00e9nerg\u00e9tique des chaudi\u00e8res commerciales et industrielles"},"content":{"rendered":"<p class=\"intro\">Le contexte environnemental et &eacute;conomique qu&eacute;b&eacute;cois nous pousse constamment &agrave; revoir nos fa&ccedil;ons de faire afin de rester comp&eacute;titif face &agrave; nos concurrents et &agrave; nos valeurs. La r&eacute;duction des co&ucirc;ts reli&eacute;s &agrave; l&rsquo;exploitation d&rsquo;une chaufferie est devenue une bonne fa&ccedil;on de r&eacute;duire les co&ucirc;ts d&rsquo;op&eacute;rations d&rsquo;une entreprise. Voici quatre moyens simples d&rsquo;y parvenir.<\/p>\n<p class=\"titre-sous\">1. Utiliser des br&ucirc;leurs &agrave; hautes performances avec une grande plage de modulation (modulation, m&eacute;lange air-gaz)<\/p>\n<p class=\"texte-courant\">Le br&ucirc;leur est une composante fondamentale dans l&rsquo;atteinte d&rsquo;une bonne efficacit&eacute; de la chaudi&egrave;re. La plage de modulation ainsi que le ratio requis entre la quantit&eacute; d&rsquo;air de combustion et de gaz naturel doivent &ecirc;tre analys&eacute;s lors de la s&eacute;lection d&rsquo;un br&ucirc;leur. Un br&ucirc;leur de bonne qualit&eacute; pourra, &agrave; l&rsquo;aide du ventilateur, m&eacute;langer l&rsquo;air de combustion et le gaz naturel de fa&ccedil;on &agrave; obtenir une combustion compl&egrave;te et propre avec une quantit&eacute; minimale d&rsquo;exc&egrave;s d&rsquo;air (10% &agrave; 15%), et ce, tout au long de sa plage de modulation. Certains br&ucirc;leurs peuvent r&eacute;duire leur puissance jusqu&rsquo;&agrave; 10% de leur puissance maximale (10:1 de taux de modulation) sans g&eacute;n&eacute;rer de perte due &agrave; un pauvre ratio de m&eacute;lange air-gaz ou &agrave; une mauvaise combustion.<\/p>\n<p class=\"texte-courant\">La figure suivante montre bien l&rsquo;impact d&rsquo;un grand ratio de modulation sur la consommation de gaz naturel.<\/p>\n<p class=\"texte-courant\"><a href=\"https:\/\/informatech.energir.com\/wp-content\/uploads\/22-1-1-graph1-fr.gif\" data-rel=\"lightbox\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-502\" title=\"22-1-1-graph1-fr\" src=\"https:\/\/informatech.energir.com\/wp-content\/uploads\/22-1-1-graph1-fr.gif\" alt=\"\" width=\"450\" height=\"252\"\/><\/a><\/p>\n<p class=\"titre-sous\">2. Am&eacute;liorer l&rsquo;efficacit&eacute; de combustion de vos br&ucirc;leurs (micromodulation, sonde O<sub>2<\/sub>, VFD)<\/p>\n<p class=\"texte-courant\">Il est possible d&rsquo;ajouter des syst&egrave;mes auxiliaires tr&egrave;s int&eacute;ressants sur un br&ucirc;leur afin de le rendre encore plus performant.<\/p>\n<p class=\"texte-courant\">Le remplacement des vieux m&eacute;canismes &agrave; levier, &agrave; bielle et &agrave; manivelle, qui sont souvent impr&eacute;cis et d&eacute;sajust&eacute;s par des servomoteurs tous ind&eacute;pendants, permet d&rsquo;optimiser le m&eacute;lange air-gaz naturel pour plusieurs points de la plage de puissance du br&ucirc;leur. De cette fa&ccedil;on, l&rsquo;exc&egrave;s d&rsquo;air est minimis&eacute;, r&eacute;p&eacute;table et stable &agrave; toutes les puissances.<\/p>\n<p class=\"tableau-titre\">Effet de la variation de la densit&eacute; de l&rsquo;air sur l&rsquo;exc&egrave;s d&rsquo;air<\/p>\n<table style=\"width: 350px;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup span=\"1\">\n<col span=\"1\" width=\"175\">\n<col span=\"1\" width=\"175\">\n<\/colgroup>\n<tbody class=\"tableau-texte\">\n<tr class=\"tableau-entete\" height=\"13\">\n<td style=\"text-align: center;\" height=\"13\">Temp&eacute;rature de l&rsquo;air de combustion (&deg;C)<\/td>\n<td style=\"text-align: center;\">Pourcentage d&rsquo;exc&egrave;s d&rsquo;air (%)<\/td>\n<\/tr>\n<tr height=\"13\">\n<td style=\"text-align: center;\" height=\"13\">4,5<\/td>\n<td style=\"text-align: center;\">25,5<\/td>\n<\/tr>\n<tr height=\"13\">\n<td style=\"text-align: center;\" height=\"13\">10<\/td>\n<td style=\"text-align: center;\">20,2<\/td>\n<\/tr>\n<tr height=\"13\">\n<td style=\"text-align: center;\" height=\"13\">26,7<\/td>\n<td style=\"text-align: center;\">15<\/td>\n<\/tr>\n<tr height=\"13\">\n<td style=\"text-align: center;\" height=\"13\">37,8<\/td>\n<td style=\"text-align: center;\">9,6<\/td>\n<\/tr>\n<tr height=\"13\">\n<td style=\"text-align: center;\" height=\"13\">48,9<\/td>\n<td style=\"text-align: center;\">1,1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"texte-courant\">Une fois que la micromodulation est install&eacute;e sur le br&ucirc;leur, la proportion optimale du m&eacute;lange est maintenue seulement lorsque la temp&eacute;rature de la chaufferie est identique &agrave; la temp&eacute;rature qu&rsquo;il faisait lors de la mise en marche du syst&egrave;me de micromodulation. Ceci est d&ucirc; au fait que le ventilateur d&rsquo;air de combustion fournit un volume d&rsquo;air constant. La masse d&rsquo;air fournie au br&ucirc;leur varie donc en fonction de la temp&eacute;rature et de la pression. Le tableau ci-haut montre l&rsquo;effet de cette variation de densit&eacute; sur l&rsquo;exc&egrave;s d&rsquo;air de combustion.<\/p>\n<p class=\"texte-courant\">Pour contrer ceci, il est possible d&rsquo;installer un syst&egrave;me de correction automatique du m&eacute;lange air-gaz naturel. L&rsquo;ajout d&rsquo;une sonde d&eacute;tectant le niveau d&rsquo;exc&egrave;s d&rsquo;air dans les produits de combustion permet d&rsquo;informer le contr&ocirc;leur de combustion et de varier la position du servomoteur modulant l&rsquo;air de combustion minimisant l&rsquo;exc&egrave;s en tout temps. Aucun ajout d&rsquo;air suppl&eacute;mentaire n&rsquo;est requis pour couvrir le syst&egrave;me contre le manque d&rsquo;air lorsque l&rsquo;air de combustion est &agrave; tr&egrave;s haute temp&eacute;rature. Afin de g&eacute;n&eacute;rer des &eacute;conomies &eacute;lectriques reli&eacute;es au ventilateur d&rsquo;air de combustion, il est possible d&rsquo;installer un variateur de fr&eacute;quence qui contr&ocirc;le la vitesse du moteur du ventilateur, plut&ocirc;t que d&rsquo;utiliser un volet de restriction sur l&rsquo;entr&eacute;e d&rsquo;air. Le potentiel d&rsquo;&eacute;conomie reli&eacute; &agrave; cette mesure est d&rsquo;environ 2% et peut varier grandement en fonction de la chaudi&egrave;re.<\/p>\n<p class=\"titre-sous\">3. Utiliser des &eacute;conomiseurs, lorsque possible (contact direct ou indirect)<\/p>\n<p class=\"texte-courant\">Les chaudi&egrave;res &agrave; vapeur traditionnelles ne peuvent normalement pas fonctionner &agrave; tr&egrave;s haute efficacit&eacute;, car les produits de combustion sortant de la chaudi&egrave;re ne peuvent techniquement pas &ecirc;tre plus froids que la temp&eacute;rature de la vapeur qu&rsquo;ils produisent. Typiquement, la temp&eacute;rature des produits de combustion &agrave; la sortie de la chaudi&egrave;re est d&rsquo;environ 55 &deg;C plus chaud que la temp&eacute;rature de saturation de la vapeur produite. Par contre, l&rsquo;eau d&rsquo;alimentation de la chaudi&egrave;re provenant du r&eacute;servoir de condensat est &agrave; environ 82 &deg;C. L&rsquo;ajout d&rsquo;un r&eacute;cup&eacute;rateur de chaleur indirecte, appel&eacute; &laquo; &eacute;conomiseur &raquo;, &agrave; la sortie de la chaudi&egrave;re permet de transf&eacute;rer une certaine quantit&eacute; de cette &eacute;nergie disponible &agrave; l&rsquo;eau d&rsquo;alimentation et ainsi de r&eacute;duire la consommation de gaz naturel. Il est aussi possible de r&eacute;cup&eacute;rer cette &eacute;nergie r&eacute;siduelle avec un r&eacute;cup&eacute;rateur &agrave; contact direct et de la transf&eacute;rer &agrave; un autre syst&egrave;me &eacute;nerg&eacute;tique qui fonctionne &agrave; basse temp&eacute;rature. Cette application est int&eacute;ressante, car il devient possible de pousser l&rsquo;efficacit&eacute; globale du syst&egrave;me &agrave; 100 %. Le potentiel d&rsquo;&eacute;conomie reli&eacute; &agrave; l&rsquo;utilisation d&rsquo;un &eacute;conomiseur &agrave; contact direct peut atteindre 20 %. L&rsquo;&eacute;conomie potentielle, qu&rsquo;un &eacute;conomiseur de type indirect peut atteindre, est de 5 % et peut varier grandement en fonction de la chaudi&egrave;re.<\/p>\n<table style=\"width: 600px;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup span=\"1\">\n<col span=\"1\" width=\"100\">\n<col span=\"1\" width=\"100\">\n<col span=\"4\" width=\"100\">\n<\/colgroup>\n<tbody class=\"tableau-texte\">\n<tr class=\"tableau-entete\" height=\"13\">\n<td style=\"text-align: center;\" rowspan=\"3\" height=\"39\">Taux de purge (%) vs l&rsquo;eau d&rsquo;approvisionnement<\/td>\n<td style=\"text-align: center;\" colspan=\"5\">&Eacute;nergie r&eacute;cup&eacute;r&eacute;e, millions de Btu\/h (MMBtu\/h)<\/td>\n<\/tr>\n<tr height=\"13\">\n<td class=\"tableau-entete\" style=\"text-align: center;\" colspan=\"5\" height=\"13\">Pression d&rsquo;op&eacute;ration de la chaudi&egrave;re (psig)<\/td>\n<\/tr>\n<tr class=\"tableau-entete\" height=\"13\">\n<td style=\"text-align: center;\" height=\"13\">50<\/td>\n<td style=\"text-align: center;\">100<\/td>\n<td style=\"text-align: center;\">150<\/td>\n<td style=\"text-align: center;\">250<\/td>\n<td style=\"text-align: center;\">300<\/td>\n<\/tr>\n<tr height=\"13\">\n<td style=\"text-align: center;\" height=\"13\">2<\/td>\n<td style=\"text-align: center;\">0,45<\/td>\n<td style=\"text-align: center;\">0,5<\/td>\n<td style=\"text-align: center;\">0,55<\/td>\n<td style=\"text-align: center;\">0,65<\/td>\n<td style=\"text-align: center;\">0,65<\/td>\n<\/tr>\n<tr height=\"13\">\n<td style=\"text-align: center;\" height=\"13\">4<\/td>\n<td style=\"text-align: center;\">0,9<\/td>\n<td style=\"text-align: center;\">1<\/td>\n<td style=\"text-align: center;\">1,1<\/td>\n<td style=\"text-align: center;\">1,3<\/td>\n<td style=\"text-align: center;\">1,3<\/td>\n<\/tr>\n<tr height=\"13\">\n<td style=\"text-align: center;\" height=\"13\">6<\/td>\n<td style=\"text-align: center;\">1,3<\/td>\n<td style=\"text-align: center;\">1,5<\/td>\n<td style=\"text-align: center;\">1,7<\/td>\n<td style=\"text-align: center;\">1,9<\/td>\n<td style=\"text-align: center;\">2<\/td>\n<\/tr>\n<tr height=\"13\">\n<td style=\"text-align: center;\" height=\"13\">8<\/td>\n<td style=\"text-align: center;\">1,7<\/td>\n<td style=\"text-align: center;\">2<\/td>\n<td style=\"text-align: center;\">2,2<\/td>\n<td style=\"text-align: center;\">2,6<\/td>\n<td style=\"text-align: center;\">2,7<\/td>\n<\/tr>\n<tr height=\"13\">\n<td style=\"text-align: center;\" height=\"13\">10<\/td>\n<td style=\"text-align: center;\">2,2<\/td>\n<td style=\"text-align: center;\">2,5<\/td>\n<td style=\"text-align: center;\">2,8<\/td>\n<td style=\"text-align: center;\">3,2<\/td>\n<td style=\"text-align: center;\">3,3<\/td>\n<\/tr>\n<tr height=\"13\">\n<td style=\"text-align: center;\" height=\"13\">20<\/td>\n<td style=\"text-align: center;\">4,4<\/td>\n<td style=\"text-align: center;\">5<\/td>\n<td style=\"text-align: center;\">5,6<\/td>\n<td style=\"text-align: center;\">6,4<\/td>\n<td style=\"text-align: center;\">6,6<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"texte-note\">Source : U.S Department of Energy. Improving steam system performance<\/p>\n<p><span style=\"font-family: DIN, 'Bitstream Charter', serif; font-size: xx-small;\"><span class=\"texte-courant\"> <\/span><\/span><\/p>\n<p class=\"titre-sous\">4. R&eacute;cup&eacute;rer l&rsquo;&eacute;nergie contenue dans l&rsquo;eau de purge de chaudi&egrave;re &agrave; vapeur<\/p>\n<p class=\"texte-courant\">L&rsquo;eau de purge, bien qu&rsquo;elle ait id&eacute;alement &eacute;t&eacute; minimis&eacute;e, contient une quantit&eacute; non n&eacute;gligeable d&rsquo;&eacute;nergie r&eacute;cup&eacute;rable. Le tableau ci-contre pr&eacute;sente le potentiel de r&eacute;cup&eacute;ration en fonction de la pression d&rsquo;op&eacute;ration de la chaudi&egrave;re et du taux de d&eacute;bit de purge pour une chaudi&egrave;re produisant 100000 lb\/h de vapeur.<\/p>\n<p class=\"texte-courant\">Cette &eacute;nergie peut &ecirc;tre r&eacute;cup&eacute;r&eacute;e &agrave; l&rsquo;aide d&rsquo;un simple &eacute;changeur de chaleur pour pr&eacute;chauffer l&rsquo;eau d&rsquo;appoint ou avec un r&eacute;servoir d&rsquo;&eacute;vaporation permettant de produire de la vapeur &agrave; plus basse pression pouvant servir &agrave; alimenter d&rsquo;autres syst&egrave;mes du b&acirc;timent, comme le d&eacute;gazeur ou des serpentins de chauffage &agrave; vapeur.<\/p>\n<p class=\"texte-courant\">Voil&agrave; donc quatre approches simples qui permettent de r&eacute;duire votre facture &eacute;nerg&eacute;tique tout en respectant l&rsquo;environnement.<\/p>\n<p class=\"texte-signature\">Martin Blanchet, ing., CEM<br>\nConseiller technique<br>\nGroupe DATECH<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Le contexte environnemental et &eacute;conomique qu&eacute;b&eacute;cois nous pousse constamment &agrave; revoir nos fa&ccedil;ons de faire afin de rester comp&eacute;titif face &agrave; nos concurrents et &agrave; nos valeurs. La r&eacute;duction des co&ucirc;ts reli&eacute;s &agrave; l&rsquo;exploitation d&rsquo;une chaufferie est devenue une bonne &hellip; <a href=\"https:\/\/dev.informatech.colpron.com\/?p=493\">Lire la suite<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[403,1],"tags":[26],"class_list":["post-493","post","type-post","status-publish","format-standard","hentry","category-informa-tech","category-uncategorized","tag-22-1-1-fr"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v16.3 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/dev.informatech.colpron.com\/?p=493\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Quatre moyens d\u2019optimiser la performance \u00e9nerg\u00e9tique des chaudi\u00e8res commerciales et industrielles | Informa-TECH\" \/>\n<meta property=\"og:description\" content=\"Le contexte environnemental et &eacute;conomique qu&eacute;b&eacute;cois nous pousse constamment &agrave; revoir nos fa&ccedil;ons de faire afin de rester comp&eacute;titif face &agrave; nos concurrents et &agrave; nos valeurs. La r&eacute;duction des co&ucirc;ts reli&eacute;s &agrave; l&rsquo;exploitation d&rsquo;une chaufferie est devenue une bonne &hellip; Lire la suite\" \/>\n<meta property=\"og:url\" content=\"https:\/\/dev.informatech.colpron.com\/?p=493\" \/>\n<meta property=\"og:site_name\" content=\"Informa-TECH\" \/>\n<meta property=\"article:published_time\" content=\"2008-03-01T18:48:27+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-04-15T13:11:55+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/informatech.colpron.ca\/wp-content\/uploads\/22-1-1-graph1-fr.gif\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture est.\">\n\t<meta name=\"twitter:data1\" content=\"5 minutes\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/dev.informatech.colpron.com\/#website\",\"url\":\"https:\/\/dev.informatech.colpron.com\/\",\"name\":\"Informa-TECH\",\"description\":\"Informa-TECH\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/dev.informatech.colpron.com\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/dev.informatech.colpron.com\/?p=493#primaryimage\",\"inLanguage\":\"fr-FR\",\"url\":\"https:\/\/informatech.energir.com\/wp-content\/uploads\/22-1-1-graph1-fr.gif\",\"contentUrl\":\"https:\/\/informatech.energir.com\/wp-content\/uploads\/22-1-1-graph1-fr.gif\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/dev.informatech.colpron.com\/?p=493#webpage\",\"url\":\"https:\/\/dev.informatech.colpron.com\/?p=493\",\"name\":\"Quatre moyens d\\u2019optimiser la performance \\u00e9nerg\\u00e9tique des chaudi\\u00e8res commerciales et industrielles | Informa-TECH\",\"isPartOf\":{\"@id\":\"https:\/\/dev.informatech.colpron.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/dev.informatech.colpron.com\/?p=493#primaryimage\"},\"datePublished\":\"2008-03-01T18:48:27+00:00\",\"dateModified\":\"2021-04-15T13:11:55+00:00\",\"author\":{\"@id\":\"https:\/\/dev.informatech.colpron.com\/#\/schema\/person\/84d663703c78185d23d8ef51e87218fe\"},\"breadcrumb\":{\"@id\":\"https:\/\/dev.informatech.colpron.com\/?p=493#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/dev.informatech.colpron.com\/?p=493\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/dev.informatech.colpron.com\/?p=493#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/dev.informatech.colpron.com\/\",\"url\":\"https:\/\/dev.informatech.colpron.com\/\",\"name\":\"Accueil\"}},{\"@type\":\"ListItem\",\"position\":2,\"item\":{\"@id\":\"https:\/\/dev.informatech.colpron.com\/?p=493#webpage\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/dev.informatech.colpron.com\/#\/schema\/person\/84d663703c78185d23d8ef51e87218fe\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/dev.informatech.colpron.com\/#personlogo\",\"inLanguage\":\"fr-FR\",\"url\":\"https:\/\/dev.informatech.colpron.com\/wp-content\/uploads\/2021\/08\/energir-2-150x150.png\",\"contentUrl\":\"https:\/\/dev.informatech.colpron.com\/wp-content\/uploads\/2021\/08\/energir-2-150x150.png\",\"caption\":\"admin\"},\"sameAs\":[\"https:\/\/informatech.colpron.com\/2021\"],\"url\":\"https:\/\/dev.informatech.colpron.com?author_name\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/dev.informatech.colpron.com\/index.php?rest_route=\/wp\/v2\/posts\/493","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dev.informatech.colpron.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dev.informatech.colpron.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dev.informatech.colpron.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dev.informatech.colpron.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=493"}],"version-history":[{"count":1,"href":"https:\/\/dev.informatech.colpron.com\/index.php?rest_route=\/wp\/v2\/posts\/493\/revisions"}],"predecessor-version":[{"id":4899,"href":"https:\/\/dev.informatech.colpron.com\/index.php?rest_route=\/wp\/v2\/posts\/493\/revisions\/4899"}],"wp:attachment":[{"href":"https:\/\/dev.informatech.colpron.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=493"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dev.informatech.colpron.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=493"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dev.informatech.colpron.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=493"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}